{"product_id":"m3n400t3","title":"M3N400T3-MCCB UL 489, M3N, 400 A Frame Size, 65kA@480Vac, 400A, 3P, lug is not included","description":"\u003ctable style=\"width: 100%; max-width: 800px; margin: 0 auto; border-collapse: collapse;\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePrimary brand\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eNOARK\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMain function\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eProduct series \/ family name\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eElectrical protection \u0026gt;  Circuit breakers \u0026gt;  AC Moulded Case Circuit Breakers (MCCBs)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSub-range name\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eEx9M3 series\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFunctions\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePoles\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e3-poles (3P3d)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTrip current rating\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e400\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFrame current rating\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e400\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated operating voltage (Ue)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e(IEC) 690\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated voltage (AC)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e600Vac\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated impulse voltage (Uimp)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e8\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated insulation voltage (Ui)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e800\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eConnection type\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eLugs on both load and line sides\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCross-section\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003econnects with #3\/0AWG (000)...500kcmil \/ 95mm2...240mm2 conductors (1-hole lugs) or #3AWG...250kcmil \/ 35mm2...120mm2 conductors (2-hole lugs)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShort circuit breaking rating\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e100kA (240Vac)\u003cbr\u003e65kA (480Vac)\u003cbr\u003e25kA (600Vac)\u003cbr\u003e50kA (600Vdc)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUltimate short circuit current breaking capacity (Icu)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e100kA (220\/240Vac)\u003cbr\u003e100kA (380\/415Vac)\u003cbr\u003e15kA (660\/690Vac)\u003cbr\u003e50kA (500Vdc)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTrip unit type\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e```Technology = Thermal-Magnetic (adjustable)\u003cbr\u003eSeries = AT\/AM (Adjustable Thermal \/ Adjustable Magnetic)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eProtection functions\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eAdjustable thermal protection (Overload)\u003cbr\u003eAdjustable threshold magnetic protection (Short-circuit)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eProtection settings\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eProtection against thermal overload -- adjustable 0.8...1 x In (320A...400A)\u003cbr\u003eMagnetic instantaneous protection against short-circuit -- adjustable 5...10 x In (2000A...4000A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensions\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eH285mm x W140mm x D116.5mm\u003cbr\u003eH11.22\" x W5.51\" x D4.59\"\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e-25°C...+70\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOrder code \/ Manufacturer SKU\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eM3N400T3L\u003cbr\u003e1100374\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eManufacturer product status\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eCommercialized\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eEquivalent to\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e1100374\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCompliant with standard(s)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eUL489 listed\u003cbr\u003eUL489 listed (file number E355392)\u003cbr\u003eCSA C22.2 No.5\u003cbr\u003eIEC\/EN 60947-2\u003cbr\u003eCE compliant\u003cbr\u003eRoHS compliant\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e5000 hours\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e8000 hours\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShort Description\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eMCCB - 1100374 - UL489 - M3 frame - 3P3d - 400A rated - 600Vdc\/ac\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eType\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eOption =  Standard (No options)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated current\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e400A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRated Voltage (DC)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e600Vdc\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eConnection type(electrical)\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eFixed\u003cbr\u003eLug connection\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNet weight\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003e6100\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCross - sells with\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eAL\/AX21P\u003cbr\u003eSHT22NA\u003cbr\u003eSHT22NB\u003cbr\u003eSHT22NC\u003cbr\u003eSHT22ND\u003cbr\u003eSHT22NE\u003cbr\u003eSHT22NGWS\u003cbr\u003eUVT22NA\u003cbr\u003eUVT22NB\u003cbr\u003eUVT22NC\u003cbr\u003eUVT22ND\u003cbr\u003eUVT22NE\u003cbr\u003eUVT22NF\u003cbr\u003eUVT22NG\u003cbr\u003eUVT22NH\u003cbr\u003eKLK23NA\u003cbr\u003eKLK23NB\u003cbr\u003eKLK23NC\u003cbr\u003eMIT23NA\u003cbr\u003eMOD23NA\u003cbr\u003eMOD23NB\u003cbr\u003eMOD23NC\u003cbr\u003eFH4XC\u003cbr\u003eFH4XD\u003cbr\u003eOMC\u003cbr\u003eOMB22\u003cbr\u003eFSB10\u003cbr\u003eNOARK-FSB2\u003cbr\u003eFSB3\u003cbr\u003eFSB4\u003cbr\u003eFSB5\u003cbr\u003eFSB6\u003cbr\u003eFSB7\u003cbr\u003eNOARK-FSB8\u003cbr\u003eFSB9\u003cbr\u003eLTC23NAA\u003cbr\u003eLTC23NBA\u003cbr\u003eLTC23NCA\u003cbr\u003eLTC23NEA\u003cbr\u003eLTC23NFA\u003cbr\u003eLK23NBA\u003cbr\u003eLK23NCA\u003cbr\u003eLK23NEA\u003cbr\u003eLK23NFA\u003cbr\u003eRCP23N\u003cbr\u003eTC23N\u003cbr\u003eTC23NB\u003cbr\u003ePIA23N\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCategory code\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eGlobal_Cat_001001001002\u003cbr\u003eElectrical components\u003cbr\u003eElectrical circuits protection\u003cbr\u003eCircuit Breakers (CB)\u003cbr\u003eMoulded Case Circuit Breakers (MCCB)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eProduct title\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eMoulded Case Circuit Breaker (MCCB) - NOARK Ex9M3 series\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDescription generating formula\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDescription\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eMoulded Case Circuit Breaker (MCCB) - UL489 listed - NOARK (Ex9M3 series) - 3-poles (3P3d) - Rated current 400A - Interrupting capacity 25kA (600Vac) - Lugs on both load and line sides - Thermal-Magnetic (adjustable) (AT\/AM (Adjustable Thermal \/ Adjustable Magnetic)) trip unit - equivalent to 1100374\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCatalogue connector\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eNOARK - Ex9M3 series\u003cbr\u003eM3N400T3L\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBenefits\u003c\/td\u003e\r\n\u003ctd style=\"font-weight: bold;\"\u003eEx9M series offers\u003cbr\u003e- High-breaking capacity and a patented arc extinguishing design\u003cbr\u003e- Bearing-type spindle reduces the operating force required to open and close the operating mechanism\u003cbr\u003e- High quality compact modular design\u003cbr\u003e- Fixed and adjustable trip unit settings\u003cbr\u003e- Line and load lugs installed standard\u003cbr\u003e- 5-Year limited warranty\u003cbr\u003e \u003cbr\u003eCertifications\u003cbr\u003e- UL 489 listed File Number E355392\u003cbr\u003e- UL listed to UL489 and Canada CSA standards 22.2 No. 5\u003cbr\u003e- IEC\/EN 60947-2\u003cbr\u003e- CE Compliant\u003cbr\u003e- UL489B, File Number E513573\u003cbr\u003e \u003cbr\u003eWide range of accessories\u003cbr\u003e- Alarm switch and auxiliary contact\u003cbr\u003e- Shunt and undervoltage trip\u003cbr\u003e- Rotary type handle\u003cbr\u003e- Flange type handle\u003cbr\u003e- Motor Operator\u003cbr\u003e- Mechanical Interlock\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n","brand":"NOARK","offers":[{"title":"Default Title","offer_id":52816048849196,"sku":"M3N400T3","price":411.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/5676\/5740\/files\/M3-3P_690913ea-171f-4110-9923-c8474873ce31.png?v=1747139680","url":"https:\/\/www.elecspro.com\/products\/m3n400t3","provider":"ELECSPRO","version":"1.0","type":"link"}