M1PVS30T3LC-1000VDC MCCB UL489B jumper connection C, M1PVS, 80 A Frame Size, 10kA @ 1000Vdc, 30A, 3P, Lug Line/Load Side
Regular price
$2,224.77 CAD
Couldn't load pickup availability
Primary brand | NOARK |
Main function | Moulded Case Circuit Breaker (MCCB) |
Product series / family name | Electrical protection > Circuit breakers > DC Moulded Case Circuit Breakers (MCCBs) |
Sub-range name | Ex9M1PVS series |
Functions | DC Moulded Case Circuit Breaker (MCCB) |
Poles | 3-poles (3P3d) |
Trip current rating | 30 |
Frame current rating | 80 |
Connection type | type "C" poles jumper connection (for both grounded and ungrounded system wirings; 3 breaker poles in series on "+" line; load connection on upper breaker pads) Lugs on both load and line sides |
Short circuit breaking rating | 10kA (at 1000Vdc) |
Trip unit type | ```Technology = Thermal-Magnetic (fixed) Series = FT/FM (Fixed Thermal / Fixed Magnetic) |
Protection functions | Fixed thermal protection (Overload) Fixed threshold magnetic protection (Short-circuit) |
Protection settings | Protection against thermal overload -- fixed at 30A Magnetic instantaneous protection against short-circuit -- fixed at 300A |
Dimensions | H238mm x W90mm x D84.5mm H9.37" x W3.5" x D3.33" |
Ambient air temperature for operation | -20°C...+50 |
Order code / Manufacturer SKU | M1PVS30T3LC 1102485 |
Manufacturer product status | Commercialized |
Equivalent to | 1102485 |
Compliant with standard(s) | UL489B listed UL489 listed (file number E355392) UL489B listed (file number E513573) CSA C22.2 No.5 IEC/EN 60947-2 CE compliant RoHS compliant |
Mechanical durability | 10000 hours |
Short Description | DC MCCB - 1102485 - UL489B - M1 frame - 3P3d - 30A rated - 1000Vdc |
Type | Option = special poles jumpers (type "C"; for both grounded and ungrounded system wirings; 3 breaker poles in series on "+" line; load connection on UPPER breaker pads) |
Rated current | 30A |
Rated Voltage (DC) | 1000Vdc (rated service voltage) |
Connection type(electrical) | Fixed Lug connection |
Net weight | 1400 |
Cross - sells with | AL/AX21P SHT21NA SHT21NB SHT21NC SHT21ND SHT21NE SHT21NI UVT21NA UVT21NB UVT21NC UVT21ND UVT21NE UVT21NF UVT21NG UVT21NH KLK21NA KLK21NB KLK21NC MIT21NA MOD21NA MOD21NB MOD21NC RHD21N1 RHD21N16 RHD21N2 FH4XC FH4XD OMC OMB21 FSB10 NOARK-FSB2 FSB3 FSB4 FSB5 FSB6 FSB7 NOARK-FSB8 FSB9 ERH21N1A ERH21N1A6 ERH21N1B ERH21N1B6 ERH21N1C ERH21N2A ERH21N2A6 ERH21N2B ERH21N2B6 ERH21N2C JPR21N |
Category code | Global_Cat_001001001002 Electrical components Electrical circuits protection Circuit Breakers (CB) Moulded Case Circuit Breakers (MCCB) |
Product title | DC Moulded Case Circuit Breaker (MCCB) - NOARK Ex9M1PVS series |
Description generating formula | A |
Description | DC Moulded Case Circuit Breaker (MCCB) - UL489B listed - NOARK (Ex9M1PVS series) - 3-poles (3P3d) - Rated current 30A - Interrupting capacity 10kA (at 1000Vdc) - type "C" poles jumper connection / Lugs on both load and line sides - Thermal-Magnetic (fixed) (FT/FM (Fixed Thermal / Fixed Magnetic)) trip unit - equivalent to 1102485 |
Catalogue connector | NOARK - Ex9M1PVS series M1PVS30T3LC |
Benefits | The NOARK Electric M1PVS is a UL489B DC MCCB, with current ratings of 15A to 80A, with a 10kA breaking capacity at 1000Vdc. Each unit is equipped with thermal magnetic trip units for protection of overload and short circuit in photovoltaic system. The M1PVS features a poles-in-series design and is equipped with pre-installed jumpers. 4 jumper connection configurations are offered for grounded and ungrounded systems. M1PVS is backed by a 5-year limited warranty. |