M1S40T3L-MCCB UL 489, M1S, 150 A Frame Size, 35kA@480Vac, 40A, 3P , Lug Line/Load Side
Regular price
$329.78 CAD
Couldn't load pickup availability
Primary brand | NOARK |
Main function | Moulded Case Circuit Breaker (MCCB) |
Product series / family name | Electrical protection > Circuit breakers > AC Moulded Case Circuit Breakers (MCCBs) |
Sub-range name | Ex9M1 series |
Functions | Moulded Case Circuit Breaker (MCCB) |
Poles | 3-poles (3P3d) |
Trip current rating | 40 |
Frame current rating | 150 |
Rated operating voltage (Ue) | (IEC) 690 |
Rated voltage (AC) | 600Vac |
Rated impulse voltage (Uimp) | 8 |
Rated insulation voltage (Ui) | 800 |
Connection type | Lugs on both load and line sides |
Cross-section | connects with #14AWG...#3/0AWG (000) / 2.5mm2...95mm2 conductors |
Short circuit breaking rating | 50kA (240Vac) 35kA (480Vac) 14kA (600Vac) 20kA (600Vdc) |
Ultimate short circuit current breaking capacity (Icu) | 50kA (220/240Vac) 50kA (380/415Vac) 5kA (660/690Vac) 25kA (500Vdc) |
Trip unit type | ```Technology = Thermal-Magnetic (fixed) Series = FT/FM (Fixed Thermal / Fixed Magnetic) |
Protection functions | Fixed thermal protection (Overload) Fixed threshold magnetic protection (Short-circuit) |
Protection settings | Protection against thermal overload -- fixed at 40A Magnetic instantaneous protection against short-circuit -- fixed at 400A |
Dimensions | H164mm x W90mm x D84.5mm H6.46" x W3.54" x D3.33" |
Ambient air temperature for operation | -25°C...+70 |
Utilisation category | A |
Order code / Manufacturer SKU | M1S40T3L 1100032 |
Manufacturer product status | Commercialized |
Equivalent to | 1100032 |
Compliant with standard(s) | UL489 listed UL489 listed (file number E355392) CSA C22.2 No.5 IEC/EN 60947-2 CE compliant RoHS compliant |
Electrical durability | 6000 hours |
Mechanical durability | 10000 hours |
Short Description | MCCB - 1100032 - UL489 - M1 frame - 3P3d - 40A rated - 600Vdc/ac |
Type | Option = Standard (No options) |
Rated current | 40A |
Rated Voltage (DC) | 600Vdc |
Connection type(electrical) | Fixed Lug connection |
Net weight | 1670 |
Cross - sells with | AL/AX21P SHT21NA SHT21NB SHT21NC SHT21ND SHT21NE SHT21NI UVT21NA UVT21NB UVT21NC UVT21ND UVT21NE UVT21NF UVT21NG UVT21NH KLK21NA KLK21NB KLK21NC MIT21NA MOD21NA MOD21NB MOD21NC FH4XC FH4XD OMC OMB21 FSB10 NOARK-FSB2 FSB3 FSB4 FSB5 FSB6 FSB7 NOARK-FSB8 FSB9 LTC21NAA LTC21NCA LTC21NFA CKLB21 LK21NCA LK21NFA RCP21N TC21N PIA21N |
Category code | Global_Cat_001001001002 Electrical components Electrical circuits protection Circuit Breakers (CB) Moulded Case Circuit Breakers (MCCB) |
Product title | Moulded Case Circuit Breaker (MCCB) - NOARK Ex9M1 series |
Description generating formula | A |
Description | Moulded Case Circuit Breaker (MCCB) - UL489 listed - NOARK (Ex9M1 series) - 3-poles (3P3d) - Rated current 40A - Interrupting capacity 14kA (600Vac) - Lugs on both load and line sides - Thermal-Magnetic (fixed) (FT/FM (Fixed Thermal / Fixed Magnetic)) trip unit - equivalent to 1100032 |
Catalogue connector | NOARK - Ex9M1 series M1S40T3L |
Benefits | Ex9M series offers - High-breaking capacity and a patented arc extinguishing design - Bearing-type spindle reduces the operating force required to open and close the operating mechanism - High quality compact modular design - Fixed and adjustable trip unit settings - Line and load lugs installed standard - 5-Year limited warranty Certifications - UL 489 listed File Number E355392 - UL listed to UL489 and Canada CSA standards 22.2 No. 5 - IEC/EN 60947-2 - CE Compliant - UL489B, File Number E513573 Wide range of accessories - Alarm switch and auxiliary contact - Shunt and undervoltage trip - Rotary type handle - Flange type handle - Motor Operator - Mechanical Interlock |