SU40NMD11F-Control unit, 2500A Frame (A25), fixed type, LSIG protection, Basic type (LED display), 200-240Vac
Regular price
$989.02 CAD
Couldn't load pickup availability
Primary brand | NOARK |
Main function | Trip unit |
Product series / family name | Electrical protection > ACBs and disconnector switches accessories > Trip units |
Sub-range name | A25 series |
Functions | Trip unit alone |
Design | basic type |
Connection type | Rear fixed-type connection pads |
Trip unit type | ```Technology = Electronic Series = Series 4.0 (LSIG) ``Protection = LSIG `Display = LED |
Protection functions | L (Long-time protection) S (Short-time protection with fixed time delay) I (Instantaneous protection) G (Ground fault protection) |
Protection settings | L - Protection against overload -- adjustable 0.4...1 x In (2s...30s) S - Protection against short-circuit with time delay -- adjustable 1.5...10 x 6Ir (0.1...0.4s; I2t or definite time) I - Instantaneous protection against short-circuit -- adjustable 2...15 x In G - Protection against earth fault -- adjustable at 500A-1200A (0.1...0.4s; I2t or definite time) |
Order code / Manufacturer SKU | SU40NMD11F 1800907 |
Manufacturer product status | Commercialized |
Equivalent to | 1800907 |
Short Description | Trip unit alone - 1800907 - basic type - 2500A frame - rear fixed connection - 208-240Vac - LED display |
Type | Option = Standard (No options) |
Supply voltage(AC) | 208Vac-240Vac |
Control Voltage (AC) | 208Vac-240Vac |
Display | LED trip indicator Arc flash maintenance mode display |
Category code | Global_Cat_001001 Electrical components Electrical circuits protection |
Product title | Trip unit alone - NOARK A25 series |
Description generating formula | A |
Description | Trip unit alone - basic type - NOARK (A25 series) - 208Vac-240Vac supply voltage - Rear fixed-type connection pads - Electronic (Series 4.0 (LSIG)) trip unit - equivalent to 1800907 |
Catalogue connector | NOARK - A25 ASD25 accessories SU40NMD11F |
Benefits | A25 trip units offer advanced electronic protection and control for power distribution and feeder protection. A25 trip unit's circuits and microprocessors measure electrical values against preset or user-selected parameters. These parameters include overload, short circuit, current unbalance, and over/under voltage/frequency. When required, A residual ground current transformer provides sensing for ground fault protection when needed. A25 trip units offer standard LS, LSI and LSIG circuit protection functions. A25 trip units can provide advanced functions like Digital Metering, Arc Flash Reduction Mode, and Zone Selective Interlocking. They also offer communication capabilities for transmitting metered values and status to monitoring or control networks. A25 trip units consist of 3 models, each offering different control, display, diagnostics, and communication options. Each model can be ordered in one of 3 protection configurations. Protection Configurations: - LI - Long Time-delay Overload, Instantaneous Short Circuit. - LSI - Long Time-delay Overload, Short Time-delay Short Circuit, Instantaneous Short Circuit - LSIG - Long Time-delay Overload, Short Time-delay Short Circuit, Instantaneous Short Circuit, Equipment Ground Fault Features: - Microprocessor based true RMS sensing - Discrete rotary trip setting dials - Cause of trip LEDs - Unit status LED - Making / breaking protection (MCR) - Ready-To-Close Indicator - Available zone selective interlocking - Available arc flash reduction mode - Available RS-485 communications - USB port for power & communication - Service short circuit protection (HSISC) |